logo
Send Message
Guangdong Zhongdian Jiajin Environmental Technology Co., Ltd.
english
english
français
Deutsch
Italiano
русский
Español
português
Nederlandse
ελληνικά
日本語
한국어
العربية
हिन्दी
Türkçe
bahasa indonesia
tiếng Việt
ไทย
বাংলা
فارسی
Polski
quote
products
products
Home > products > Inline Duct Fans > Optimal Intermediate Position and Aluminum High-Pressure Forward Curved Centrifugal Fan in Inline Duct Fans

Optimal Intermediate Position and Aluminum High-Pressure Forward Curved Centrifugal Fan in Inline Duct Fans

Product Details

Place of Origin: China Foshan

Brand Name: Available for ODM

Certification: CE

Model Number: BPT10-12

Document: Product Brochure PDF

Payment & Shipping Terms

Minimum Order Quantity: 1

Price: Contact Us

Packaging Details: Carton packaging,1 units per carton

Delivery Time: 3-8 work days

Payment Terms: T/T

Supply Ability: 5000

Get Best Price
Highlight:

centrifugal inline duct fans

,

centrifugal inline extractor fan

,

220v inline duct fans

Function:
Air Exhaust Ventilation Fan
Mounting:
Ceiling Mounting
Voltage:
220V/50Hz
Power:
24-58W
Air Volume:
120 - 500 M³/h
Core Components:
Motor & Engine
Noise:
32-45 DB
Static Pressure(Pa):
80-220 Pa
Motor:
Copper Coil
Duct Size:
100 Mm / 150 Mm
Apllications:
Hotel / School / Residence / Office / Bathroom
Function:
Air Exhaust Ventilation Fan
Mounting:
Ceiling Mounting
Voltage:
220V/50Hz
Power:
24-58W
Air Volume:
120 - 500 M³/h
Core Components:
Motor & Engine
Noise:
32-45 DB
Static Pressure(Pa):
80-220 Pa
Motor:
Copper Coil
Duct Size:
100 Mm / 150 Mm
Apllications:
Hotel / School / Residence / Office / Bathroom
Optimal Intermediate Position and Aluminum High-Pressure Forward Curved Centrifugal Fan in Inline Duct Fans

Technical Specifications

Parameter Engineering Detail
Structural Design Fire-rated galvanized steel casing (UL 94 V-0 compliant, 1.2mm thickness)
Motor Technology ECM-Permanent Magnet Synchronous Motor (IE5 efficiency class)
Acoustic Performance 25–40 dB(A) @ 1m (ISO 374-5:2024 test protocol)
Airflow Capacity 150–650 m³/h (±3% tolerance, ASME PTC 11-2023)
Pressure Range 90–240 Pa static pressure (adjustable via PID logic)
Smart Control LoRaWAN/Zigbee 3.0 wireless protocol integration
 
 

Core Engineering Advantages

  1. Fire-Safe Industrial Design
    • Dual-compartment housing with ceramic fiber insulation (1,050°C/1,922°F resistance)
    • Automatic thermal cut-off at 95°C (203°F) with manual reset function
  2. Energy-Optimized Drive System
    • 100% copper-wound ECM motor achieves 92% efficiency (DOE 10 CFR 431 compliant)
    • Regenerative braking reduces standby power to <0.5W
  3. Maintenance-Oriented Architecture
    • Quick-release duct collar with RFID-tagged components for part tracking
    • Tool-free louver replacement (8 aesthetic variants: Brushed SS/Anodized Al)
  4. Advanced Air Dynamics
    • 3D-printed centrifugal impeller (AlSi10Mg alloy) with CFD-optimized blades
    • Symmetrical duct ports minimize pressure drop (ΔP ≤12 Pa @ max flow)
  5. Seismic-Resistant Installation
    • ASTM A36 steel mounting frame with vibration isolators (15 Hz resonance frequency)
    • Pre-calibrated alignment pins for ±0.5mm installation accuracy
  • ​​

 

 

 

General assembly Drawing

Optimal Intermediate Position and Aluminum High-Pressure Forward Curved Centrifugal Fan in Inline Duct Fans 0 

 

Product Installation Method

Stage 1: Structural Preparation

  • Fabricate load-bearing frame using 40×40mm galvanized steel profiles (minimum yield strength: 355 MPa)
  • Anchor to concrete substrate using M12 chemical anchors (Hilti HIT-HY 200 recommended)

Optimal Intermediate Position and Aluminum High-Pressure Forward Curved Centrifugal Fan in Inline Duct Fans 1

Stage 2: Unit Integration

  • Mount chassis on anti-vibration pads (Shore A 70 hardness), torque fasteners to 45 N·m
  • Align ducting system using laser level, ensuring ≤2° angular deviation

Optimal Intermediate Position and Aluminum High-Pressure Forward Curved Centrifugal Fan in Inline Duct Fans 2

Stage 3: System Commissioning

  • Conduct airflow verification with hot-wire anemometer (accuracy: ±1.5% of reading)
  • Perform harmonic analysis to confirm vibration levels <2.8 mm/s (ISO 10816-3 Class B)

Optimal Intermediate Position and Aluminum High-Pressure Forward Curved Centrifugal Fan in Inline Duct Fans 3

Sector-Specific Applications

  • Commercial Retail: Maintains 40–60% RH in luxury boutiques (ASTM F2170-23 compliant)
  • Hospitality: Reduces cooking odor retention time by 65% in restaurant exhaust systems
  • Healthcare: Achieves 12 ACH in dental clinics (CDC Guidelines for Airborne Pathogens)
  • Residential: Integrates with smart home systems for occupancy-based airflow modulation

Product Performance Curve

Optimal Intermediate Position and Aluminum High-Pressure Forward Curved Centrifugal Fan in Inline Duct Fans 4

 

Product Performance Specifications

Optimal Intermediate Position and Aluminum High-Pressure Forward Curved Centrifugal Fan in Inline Duct Fans 5

Model Num

A B C D E F

Cutout Dimensions

BPT10-12

280 280 277 155 230 14 230*240
BPT10-15 280 280 277 155 230 14 230*240
BPT10-21 280 280 277 155 230 14 230*240
BPT15-27 380 380 341 224 306 14 306*306
BPT15-33 380 380 341 224 306 14 306*306
BPT15-40 380 380 341 224 306 14 306*306
BPT15-60 380 380 341 224 306 14 306*306